  • 摘要: 目的 为了解决特殊场景下数据中心的配电架构,需提出一种全新的设计方案。数据中心配电设计目前已经相当成熟,早已进入标准化设计阶段,各种典型设计与标准设计已经发布,可以满足低压配电设计中大部分情况,常规设计已无过多创新点。但标准设计中不含一些特殊场景,如因投资问题引发的限额供电问题。 方法 依托具体项目,在限额供电的背景下采用资源池概念进行架构重新设计。 结果 研究结果表明:资源池架构系统可以简化远期扩容方案、降低工程造价、提高供电可靠性。 结论 新架构可以满足前端限额供电的特殊背景,并具有非常高的经济性与安全性,可以为类似工程提供借鉴。

     

    Abstract: Introduction In order to solve the distribution structure of IDC in special situations, a new design has been proposed. Now the IDC distribution power grid design is already quite mature, which is in the stage of standard design. A variety of typical designs and standard designs have been published, so most of the situation in low voltage distribution design can be satisfied, the traditional design doesn't have too much innovation. However, the standard design does not cover some special scenes, such as the problem of limited power supply caused by the investment problem. Method Based on a specific project, this paper redesigned power grid structure with the concept of resource pool under the background of limited power supply. Result According to the special situation of this paper, we design a new IDC distribution structure and optimize the long-term transformation plan. Conclusion The new structure can satisfy the special situation such as the limited power supply, and which has very high economy and security. The new structure can provide reference for other similar projects.

     

/