高级检索

高压直流换流站阀厅双层屏蔽巡视走道应用研究

Research on Application of Double-Layer Shielding Cage for Valve Hall in HVDC Converter Station

  • 摘要:
      目的  为了减小高压直流换流站阀厅占地面积并降低投资成本,提出了一种适用于高压直流换流站阀厅的双层屏蔽巡视走道方案。
      方法  在借鉴1100kV昌吉—古泉特高压直流输电工程首次应用双层屏蔽巡视走道的成功经验,以及国内科研单位开展的试验结果基础上,针对阀厅内不同巡视走道方案开展经济性对比,验证本方案的经济性。
      结果  结果证明文章提出的双层屏蔽巡视走道方案具备一定的优势。
      结论  文章提出的一种高压直流换流站阀厅采用双层屏蔽巡视走道的具体实施方案,并在某工程的阀厅中得以成功应用,具备推广价值。

     

    Abstract:
      Introduction  In order to reduce the land acquisition and cost of valve hall for HVDC converter station, a double-layer shielding cage scheme for valve hall of UHVDC converter station is presented in this paper.
      Method  With the base of successful application of double-layer shielding cage in the ±1100 kV UHVDC Changji-Guquan transmission projects, and relative experiment conducted by China power research institute, the economic comparison of various kinds of shielding cages in valve hall was carried out to verify the economy of this scheme.
      Result  The result shows that the double-layer shielding cage scheme has certain advantages.
      Conclusion  The detailed implementing scheme of the double-layer shielding cage for valve hall in HVDC converter station presented in this paper is successfully applied in one project with popularization value.

     

/

返回文章
返回