某350 MW供热机组单双列风机配置分析

Analysis on Single or Double Row Fan Configuration for a 350 MW Heat Supply Unit

  • 摘要:
      目的  为了分析某350 MW超临界供热机组风机配置的合理性。
      方法  结合风机可靠性、供热要求以及最小年费分析法,对单列风机配置和双列风机配置进行对比。
      结果  结果表明:单列风机不停机可靠率比双列风机略低,但在高负荷运行的工况下,单列风机供热可靠性反而更高。单列风机配置经济性优势明显。对长时间运行在高负荷的供热机组来说,采用单列风机配置合理性更高。
      结论  研究结论不仅适用于本工程,还可为其它供热机组提供参考。

     

    Abstract:
      Introduction  In order to analyze the reasonbility of the fan configuration of a 350 MW supercritical heating unit.
      Method  In this paper, the single-row configuration and double-row fan configuration was compared, it took the reliability of fans, the requirements of engineering heating and minimum annual fee method into congsideration.
      Result  The results demonstrate that the unstopped reliability rate of single-row fan configuration is slightly lower than double-row fan configuration. However, under the condition of high load operation, the heating supply reliability of single-row fan is higher.Single-row fan configuration econmic advantage is obvious.Therefore, it is more reasonable to adopt single-row fan for heating units which operats under high load operation for a long time.
      Conclusion  The conclusion of this study is not only applicable to this project, but also can provide guidance for other heating unit.

     

/