ZHANG Qingli. Switching Overvoltage Simulation Analysis and ComparisionBetween Matlab/SPS and EMTP[J]. SOUTHERN ENERGY CONSTRUCTION, 2015, 2(S1): 35-37,92. doi: 10.16516/j.gedi.issn2095-8676.2015.S1.008
Citation: ZHANG Qingli. Switching Overvoltage Simulation Analysis and ComparisionBetween Matlab/SPS and EMTP[J]. SOUTHERN ENERGY CONSTRUCTION, 2015, 2(S1): 35-37,92. doi: 10.16516/j.gedi.issn2095-8676.2015.S1.008

Switching Overvoltage Simulation Analysis and ComparisionBetween Matlab/SPS and EMTP

doi: 10.16516/j.gedi.issn2095-8676.2015.S1.008
  • Received Date: 2015-08-01
  • This article represents the simulation model of switching over voltage in black start process by implementing Matlab/psb model and EMTP software separately. Comparing the EMTP with an analyzed simulation of a real system could prove the reliability of Matlab/psb result for an over voltage simulation, and Matlab/psb could be one of the powerful instrument for a power system simulation. Meanwhile it could be concluded that lightning protector would effectively reduce over voltage for several fold, and make switch close successful in early stage during black start.
  • 通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

Article Metrics

Article views(341) PDF downloads(218) Cited by()

Related

Switching Overvoltage Simulation Analysis and ComparisionBetween Matlab/SPS and EMTP

doi: 10.16516/j.gedi.issn2095-8676.2015.S1.008

Abstract: This article represents the simulation model of switching over voltage in black start process by implementing Matlab/psb model and EMTP software separately. Comparing the EMTP with an analyzed simulation of a real system could prove the reliability of Matlab/psb result for an over voltage simulation, and Matlab/psb could be one of the powerful instrument for a power system simulation. Meanwhile it could be concluded that lightning protector would effectively reduce over voltage for several fold, and make switch close successful in early stage during black start.