Zufeng XIA, Shaoping LI, Xiaowen WANG, Jie YANG, Yugang SUN. General Consideration for Seismic Input of NPP Seismic Design and Seismic-isolated Research for AP1000 Nuclear Island[J]. SOUTHERN ENERGY CONSTRUCTION, 2017, 4(3): 1-6. doi: 10.16516/j.gedi.issn2095-8676.2017.03.001
Citation:
|
Zufeng XIA, Shaoping LI, Xiaowen WANG, Jie YANG, Yugang SUN. General Consideration for Seismic Input of NPP Seismic Design and Seismic-isolated Research for AP1000 Nuclear Island[J]. SOUTHERN ENERGY CONSTRUCTION, 2017, 4(3): 1-6. doi: 10.16516/j.gedi.issn2095-8676.2017.03.001
|
General Consideration for Seismic Input of NPP Seismic Design and Seismic-isolated Research for AP1000 Nuclear Island
- Received Date: 2016-10-20
- Publish Date:
2020-07-18
-
Abstract
Current situation and developing trends of the seismic input of nuclear power plant are firstly introduced and analysed in U. S.A., Japan and China. Taking the seismic-isolated foundation project of nuclear island as the example in Shanghai Nuclear Engineering Research & Design Institute, the article mainly focuses on the necessity research and general concept design of nuclear island seismic-isolated foundation for AP1000 units. Then the main content of seismic-isolated foundation from U. S. Nuclear Regulatory Commission and countermeasures from Shanghai Nuclear Engineering Research & Design Institute are researched. This work provides some guidance for further study on seismic input of nuclear power plant and seismic-isolated foundation of nuclear island as a reference.
-
References
[1]
|
夏祖讽. 美国核电厂抗震主系统分析要求的近期变化——SRP3.7.2 1989版、2007版及2013版主要对比 [J]. 南方能源建设,2016, 3(4): 1-7.
XIA Z F. Recent changes of seismic system analysis SRP 3.7.2 in 1989, 2007 and 2013 versions for NPPs in U.S.A. [J]. Southern Energy Construction, 2016, 3(4): 1-7. |
[2]
|
U.S. Nuclear Regulatory Commission. Design response spectra for seismic design of nuclear power plants: Regulatory guide 1.60 [S]. Washington D.C.: U.S. Nuclear Regulatory Commission, 1973: 1-6. |
[3]
|
U.S. Nuclear Regulatory Commission. Identification and characterization of seismic sources and determination of safe shutdown earthquake ground motion: Regulatory guide 1.165 [S]. Washington D.C.:U.S.Nuclear Regulatory Commission, 1997. |
[4]
|
American Society of Civil Engineers. Seismic design criteria for structures, system, and components in nuclear facilities: ASCE/SEI 43-05 [S/OL]. Virginia: American Society of Civil Engineers,2005. http://ascelibrary.org/doi/pdf/10.1061/9780784407622.fm. |
[5]
|
U.S. Nuclear Regulatory Commission. A performance-based approach to define the site-specific earthquake ground motion: Regulatory guide 1.208 [S]. Washington D.C.: U.S. Nuclear Regulatory Commission: 2007. |
[6]
|
KENNDY R P. Risk (performance-goal) based approach for establishing the design basis response spectrum for future nuclear power plants [R].U.S.A: RIC, 2006. |
[7]
|
PARK Y J, HOFMAYER C H. Technical guide lines for aseismic design of nuclear power plants: Translation of JEAG 4601-1987 [Z]. Washington D.C.: U.S. Nuclear Regulatory Commission, 1994. |
[8]
|
山本知史,古川茂,岛本龍,等. 次世代轻水反应堆核电厂隔震技术的开发(PART-1)隔震技术的开发计划[C]//日本建筑学会大会学术论文集. 日本:出版者不祥,2010: 1131-1132. |
[9]
|
夏祖讽,王明弹,王晓雯. 带闭锁功能的核电厂核岛结构基础隔震装置:201546235U [P]. 2010-08-11. |
[10]
|
ANNIE K, ANDREW W, MICHAEL C. Technical considerations for seismic isolation of nuclear facilities(draft for comment)[R]. U.S.A.: Office Nuclear Regulatory Research, 2012. |
[11]
|
ANIL K C, MICHAEL F, MASAYOSHI N. Earthquake Engineering and Structural Dynamic [J]. England: John Wiley & Sons Ltd, 2006-2013. |
[12]
|
American Society of Civil Engineers. Seismic analysis of safety-related nuclear structures and commentary: ASCE 4-98 [S]. Virginia: American Society of Civil Engineers, 2000. http://ascelibrary.org/doi/pdf/10.1061/9780784404331.fm. |
-
-