• Peer Review
  • Non-profit
  • Global Open Access
  • Green Channel for Rising Stars
Volume 4 Issue S1
Jul.  2020
Turn off MathJax
Article Contents

HU Rong, CHEN Fei. 220 kV GIS Compact Indoor Layout Research with Overhead Line[J]. SOUTHERN ENERGY CONSTRUCTION, 2017, 4(S1): 73-77,83. doi: 10.16516/j.gedi.issn2095-8676.2017.S1.014
Citation: HU Rong, CHEN Fei. 220 kV GIS Compact Indoor Layout Research with Overhead Line[J]. SOUTHERN ENERGY CONSTRUCTION, 2017, 4(S1): 73-77,83. doi: 10.16516/j.gedi.issn2095-8676.2017.S1.014

220 kV GIS Compact Indoor Layout Research with Overhead Line

doi: 10.16516/j.gedi.issn2095-8676.2017.S1.014
  • Received Date: 2017-09-21
  • Publish Date: 2020-07-18
  • Statistical dates show that the failure rate and defect rate of 220 kV GIS are obviously higher when arranged outdoor than indoor, while the occupied area and civil engineering investment of indoor layout increase significantly. The research of compact indoor layout scheme in this paper is based on the investigation results of five 220 kV GIS domestic mainstream manufacturers. Research results including:optimization of 220 kV GIS room width to 11 meters, recommend using double or glyph overhead line when the field width is limited, recommend cancelling independent architecture of outlet and inlet line and decorating the outlet line equipment on the roof when the field length is limited, etc. The above research results can be applied to solve the reserve site tension situation of the 220 kV GIS indoor layout, and further reduce the cost of civil engineering while improving the economic benefit of whole life cycle.
  • 通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

Article Metrics

Article views(357) PDF downloads(40) Cited by()

Related

220 kV GIS Compact Indoor Layout Research with Overhead Line

doi: 10.16516/j.gedi.issn2095-8676.2017.S1.014

Abstract: Statistical dates show that the failure rate and defect rate of 220 kV GIS are obviously higher when arranged outdoor than indoor, while the occupied area and civil engineering investment of indoor layout increase significantly. The research of compact indoor layout scheme in this paper is based on the investigation results of five 220 kV GIS domestic mainstream manufacturers. Research results including:optimization of 220 kV GIS room width to 11 meters, recommend using double or glyph overhead line when the field width is limited, recommend cancelling independent architecture of outlet and inlet line and decorating the outlet line equipment on the roof when the field length is limited, etc. The above research results can be applied to solve the reserve site tension situation of the 220 kV GIS indoor layout, and further reduce the cost of civil engineering while improving the economic benefit of whole life cycle.

HU Rong, CHEN Fei. 220 kV GIS Compact Indoor Layout Research with Overhead Line[J]. SOUTHERN ENERGY CONSTRUCTION, 2017, 4(S1): 73-77,83. doi: 10.16516/j.gedi.issn2095-8676.2017.S1.014
Citation: HU Rong, CHEN Fei. 220 kV GIS Compact Indoor Layout Research with Overhead Line[J]. SOUTHERN ENERGY CONSTRUCTION, 2017, 4(S1): 73-77,83. doi: 10.16516/j.gedi.issn2095-8676.2017.S1.014

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return